Fitted with integral single pen chart recorder with isolation valve. Supplied with 50 recorder charts and one black chard recorder pen. Infinitely variable output pressure and fluid displacement speed. Integral inlet air filtration and lubrication unit with air pressure gauge. Airline regulator for easy setting of input air and output hydraulic pressure. Mximum air consumption of 0.79 m3 (28 scfm) per minute at 7 bar. Smooth and easily operated hydraulic pressure hold and release valve. Fitted with input air pump start/stop valve for easy and fast pressure shut off. Robust powder coated stainless steel protective framework. Lightweight plastic, 7.5 litres capacity, fluid reservoir. Optional stainless steel reservoir, stroke counter system and pressure isolation valve available on request.
Technical specifications
Model | Max. output pressure (bar) at airline input pressure | Fluid volume displacement per stroke | Outlet port thread | Weight | ||
---|---|---|---|---|---|---|
10 psi 0.69 bar |
50 psi 3.45 bar |
100 psi 6.9 bar |
[cm3] | [kg] | ||
AHP10-CR | 6 | 34 | 69 | 42.3 | 1/2″ NPT | 31 |
AHP26-CR | 14 | 90 | 181 | 16 | 1/2″ NPT | 29 |
AHP36-CR | 17 | 122 | 250 | 12.3 | 1/2″ NPT | 28 |
AHP58-CR | 28 | 200 | 400 | 7.6 | 1/2″ NPT | 28 |
AHP107-CR | 62 | 373 | 738 | 4 | 1/2″ NPT | 28 |
AHP187-CR | 97 | 638 | 1293 | 2.2 | 9/16″ – 18 UNF | 28 |
AHP275-CR | 155 | 931 | 1897 | 1.6 | 9/16″ – 18 UNF | 28 |
AHP425-CR | 345 | 1448 | 2931 | 1 | 9/16″ – 18 UNF | 28 |